Skip to main content
Skip table of contents

Equipment Grid

This tab will only be available on Equipment types that have Cabling associated with the piece of Equipment.

Add

More information on Add Form is available here

Ranges

The 'Ranges' button

 is very similar to the 'Add' button but has some additional functionality. The 'Ranges' button will allow a User to Add multiple Ports/Pins/Lens(PPL) with a single action to save time when adding large lists of PPL. The Range form will allow the User to designate a low to high prefix range to be added. (For example 1-3). Additionally, the User can designate a separator (Example: " - " ) and a low to high suffix. (For example 1-5).

Assuming a prefix Range of 1-3, a separator of " - ", and a low to high suffix of 1-5 the User would be adding 15 records with the 'Save New' button

 . In this case the following would be added:

Example Ports/Pins/Lens

Suffix of '1'

Suffix of '2'

Suffix of '3'

Suffix of '4'

Suffix of '5'

Prefix of '1'

1-1

1-2

1-3

1-4

1-5

Prefix of '2'

2-1

2-2

2-3

2-4

2-5

Prefix of '3'

3-1

3-2

3-3

3-4

3-5

The 'Ranges' is more than a simple Add form, however, and will allow the User to edit multiple PPL. If after adding the above table the User were to click the Ranges button again and enter a prefix of 2-3, and a suffix of 1-1 they would select the 2-1 and 3-1 PPL for editing. This functionality allows the User to quickly Add and assign status' to multiple PPL.

Copy

The 'Copy' button

 makes a copy of all the existing PPL on another piece of Equipment and will assign the copied PPL to the current piece of Equipment. These copied PPL will not overwrite any existing PPL and instead appear as new, separate records.

Transfer

The 'Transfer' button

 will move all the existing Ports/Pins/Lens(PPL) from one piece of Equipment and assign them to the current piece of Equipment. This button can also be used to renumber PPL on the same piece of Equipment.

To Transfer PPL follow these steps:

  1. Click the 'Transfer'  button.

  2. This will open the 'Add new Select Equipment and Range to Transfer (move) the Ports/Pins/Lens' form. (Transfer PPL form for short.)

  1. The 'Origination Equipment' picker will automatically fill in with the Equipment from the open Equipment form.

  2. Click the 'Destination Equipment' picker and select the Equipment that the PPL need to be transferred to.

  3. Select a Destination piece of Equipment that is different from the Origination Equipment.

  4. Select the Origination Port/Pin/Len Range.

    • Enter the Low PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the Low PPL is named "123-ABC" where "-" is the separator, then the formatting should look like this: Low Separator: 123, Separator: -, *Low Suffix:*ABC.

    • Enter the High PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the High PPL is named "124-ABZ" where "-" is the separator, then the formatting should look like this: High Separator: 124, and *High Suffix:*ABZ.

  5. Select the Destination Port/Pin/Len Range.

    • Enter the Low PPL of the PPL records that should be created on the new Equipment record after the Transfer. This range should be set in the same manner as previously discussed.

  6. Click the 'Transfer Range'  button.

The selected range will transfer to the Destination Equipment.

Transfer Ranges

This functionality was changed for version 2.1.4.7

The Transfer Range

 button will move all the existing Ports/Pins/Lens(PPL) from one piece of Equipment and assign them to the current piece of Equipment. This button can also be used to renumber PPL on the same piece of Equipment.

To Transfer a PPL Range, follow these steps:

  1. Click the Transfer Range button. 

  2. This will open the Add New Select Equipment and Range to TRANSFER (move) the Ports/Pins/Lens form. (PPL Range Transfer Form for short.)

  3. The Origination Equipment picker will automatically fill in with the Equipment from the open Equipment form.

  4. Click the Destination Equipment picker and select the Equipment that the PPL need to be transferred to.

  5. Be sure to select a Destination piece of Equipment that is different from the Origination Equipment.

  6. Select the Origination Port/Pin/Len Range.

  7. Enter (at minimum) Low Prefix and High Prefix of the PPL records that should be selected to Transfer.


    1. Separator, Low Suffix, and High Suffix are optional fields that increase the flexibility of ranges.

    2. This needs to specify the proper format for the PP. Generally, this format is based on the organization's naming conventions.

    3. For example, the range shown above represents Low PPL named A-01 with a range of 30 ports ending on C-10.

  8. Select the Destination Port/Pin/Len (PPL) Range.

  9. Enter (at minimum) the Low Prefix of the port range the newly transferred PPLs will start at.


    1. Separator and Low Suffix are optional fields that increase the flexibility of ranges.

    2. This needs to specify the proper format for the PP. Generally, this format is based on the organization's naming conventions.

    3. For example, the range is shown above (in conjunction with the Origination Range) represents Low PPL named D-11 with a range of 30 ports ending on F-20

  10. Click the Transfer Range button to complete the transfer

  11. The selected range will be transferred to the Destination Equipment with the specified new starting port 

Transfer All

The Transfer All button

 allows transferring every PPL on an Origination Equipment to a Destination Equipment. The purpose of the form is to eliminate a few steps when the user simply needs to move ALL of the ports.

To transfer all PPLs on Equipment, use the following steps.

  1. Click the Transfer All button. 

  2. The Origination Equipment picker will automatically fill in with the Equipment from the open Equipment form.

  3. Select the Destination Equipment Using the picker

  4. Click the Transfer All Ports/Pins/Lens button to complete the transfer 

  5. All PPLs will be transferred, as is, to the Destination Equipment.

Renumber

Users can quickly renumber PPL with the Transfer form.

  1. Click the 'Transfer'  button.

  2. This will open the 'Add new Select Equipment and Range to Transfer (move) the Ports/Pins/Lens' form. (Transfer PPL form for short.)

  1. The 'Origination Equipment' picker will automatically fill in with the Equipment from the open Equipment form.

  2. Click the 'Destination Equipment' picker and select the Equipment that the PPL need to be transferred to.

  3. Select a Destination piece of Equipment that is the same Equipment as the Origination Equipment.

  4. Select the Origination Port/Pin/Len Range.

    • Enter the Low PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the Low PPL is named "123-ABC" where "-" is the separator, then the formatting should look like this: Low Separator: 123, Separator: -, *Low Suffix:*ABC.

    • Enter the High PPL of the PPL records that should be selected to Transfer. This needs to include the proper format for the PPL based on the organizations naming conventions. For example, if the High PPL is named "124-ABZ" where "-" is the separator, then the formatting should look like this: High Separator: 124, and *High Suffix:*ABZ.

  5. Click the 'Transfer Range'  button.

The selected Range will be renumbered and remain on the original Equipment record since the Origination Equipment and Destination Equipment fields match.

Managing Ports/Pins/Lens

Edit Selected

The 'Edit Selected' button

 will allow the editing of a single PPL record. A User can only edit the single record, and if multiple records editing is desired the Ranges button should be used.

Delete Selected

The 'Delete Selected' button

 will allow the User to delete the selected record(s). This deletion is not just the association and will remove the PPL from PCR-360.

Service Desk

The 'Service Desk' button

 will open the Service Desk Action associated with the PPL. This button will only open the Service Desk Action once the PPL has its Status effected by the Service Desk. Once a PPL has been designated in Service Desk, it cannot be selected to be added to a different piece of Equipment. This helps to prevent duplicate assignments.

View Path

  • The View Path button will open up the Cable: View Path report that the given Ports/Pins/Lens record appears on.

  • For a Ports/Pins/Lens record to have a Path associated with it it must first have a Status of Assigned.

  • more Information about paths and the report is available here

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.